Electrical Wiring:
 Enlarge Photo
|
|
All wall and roof panels have 1-1/2" wire chases running inside the panels. Each chase is marked on the interior side of the panels. |
| |
 Enlarge Photo
|
|
During panel installation, it is very crucial that the top plates are drilled before the roof system or second level floor system is in place. |
| |
 |
|
If the walls are to be wired from below the walls, it is necessary to drill out the base plate with a spade bit while setting panels. Measure the wire chase in the panel and drill the plate as each panel is set. |
| |
 Enlarge Photo
|
|
If roof panels are used, use top gap between wall panels and roof panels as a gutter for wiring. Then fill in gap after wiring is complete. |
| |
 |
|
The easiest way to cut out boxes in the panels is to set up a jig and use a plunge router. |
| |
 Enlarge Photo
|
|
If it is necessary to access a horizontal chase from a vertical chase, run wire down vertical chase and then drill out a small plug at the junction of the vertical and horizontal. Then reach inside panel and turn the wire and push down the chase. |
| |
 |
|
Cut all boxes in panels before wiring, then run wiring to the boxes. |
| |
 |
|
It is recommended that any chases accessed from the outside be filled with insulation after the wires have been run. |
| |
 |
|
Cut as little OSB as possible when wiring. If necessary, OSB can be routed horizontally, but this takes away from the structure of the panel, so do not make long runs in this fashion. |
| |
 Enlarge Photo
|
|
Wall panels have set heights of 16" and 46" for horizontal chases in every panel. Specialized chases can be installed in the panel upon customer request. |
| |
 Enlarge Photo
|
|
Use a flex bit to drill out wire chases that do not exist in the location where you need it at. |
| |
|
 |
 |
 |
Contact Us at:
IB Panels ®
PO Box 723
50 West 100 South
Jerome, ID 83338
PH: 208-324-7184
FAX: 208-324-6740
Toll Free: 888-799-1398
News from IB Panels ®
Habitat for Humanity - "Blitz Build" was completed in 108 hours. IB Panels ® were used for the floors and walls. The walls were stood up within 45 minutes. Article 1 - Article 2 - Article 3.
 View This Cabin
Up to 50% more energy efficient.
Approximately 40% less on-site labor.
Highly efficient, insulated corners, patented design.
ICC # PFC 5361
Oregon Registration # M397
Quality Control Agency - PFS Corporation
Madison, Wisconsin #98-33


|
 |
 |